Error management
©
by Antriebs- & Regeltechnik Schimpf GmbH
66
Error
Possible cause
Solution
Error found during
plausibility check
Check the individual setting
based on the flashing
sequence of the “Enable” LED.
See the section “Plausibility
check”
The drive
continuously corrects
the current position in
control mode.
Fluctuations in the
analogue input signal
Check the analogue input
signal.
If necessary, increase the
“Hysteresis” setting.
If necessary, increase the
“Averaging” setting.
The analogue output
does not show the
expected values.
The settings for the
analogue signal are not
set correctly.
If necessary, adjust the
“Analogue signal” setting.
If necessary, adjust the
“Analogue signal” setting of the
DIP switch.
If necessary, calibrate the
analogue output.
The drive does not
move in the operating
modes “control with
setpoint enabling”
(parameter 2) or
“three-point step with
enabling” (parameter
3).
There is no enable signal
at terminal 12.
Check the enable signal. The
“Enable” LED can also be
used for this purpose.
If necessary, change to a
mode without an enable signal.
Содержание 00-10/30 STEP
Страница 28: ...Connections by Antriebs Regeltechnik Schimpf GmbH 28 Figure 10 CPU board 00 15 Figure 11 Add on board 00 15 ...
Страница 69: ...Declaration of Conformity by Antriebs Regeltechnik Schimpf GmbH 69 Declaration of Conformity ...
Страница 71: ...Dimensional drawing by Antriebs Regeltechnik Schimpf GmbH 71 Figure 15 Dimensions of drive type 00 15 ...
Страница 72: ...Dimensional drawing by Antriebs Regeltechnik Schimpf GmbH 72 Figure 16 Dimensions of drive type 01 15 ...