Operation
©
by Antriebs- & Regeltechnik Schimpf GmbH
53
Configuration mode 2
Set the actuator to
configuration mode 2
if you want to change any other settings. To
set the actuator to
configuration mode 2
while it is already running, set the Mode and
Parameter rotary switches to
“0”
, then press and hold the
and
“PROG”
buttons at
the same time.
You can also set the actuator to
configuration mode 2
as you turn it on (apply a
voltage) by pressing the
button with the Mode and Parameter rotary switches set
to
“0”
.
The “PROG” LED and the “Enable” LED will be on. The “Ready for operation” relay is
not switched. You can then use the Parameter rotary switch to select different settings.
Press and hold
the “Prog” button to save your settings. The “Prog” LED will flash briefly
to show that your settings have been saved.
To exit
configuration mode 2
, set the Mode and Parameter rotary switches back to
“0”, then press and hold the “Prog” button. The “Prog” LED will flash briefly. The
actuator will then return to standard mode.
An overview of the different options available for the parameters is provided in the table
below: