Operation
©
by Antriebs- & Regeltechnik Schimpf GmbH
59
Press and hold the “Prog” button to set the value.
The “Prog” LED will flash briefly.
+ -
The current 10 V value is output. The displayed
value must be set to 10 V as accurately as
possible. The value can be decreased using the
button and increased using the
button.
Press and hold the “Prog” button to store the new
calibration values for 2 and 10 V in the memory.
The “Prog” LED will flash briefly.
Parameters 2-9:
Not assigned; when selected, the current setting is not changed
Mode 3: Calibrate analogue input 4 mA or 2 V value
The analogue input of the drive is calibrated at the factory.
Recalibrating the
analogue input is usually only necessary if there are very high requirements for angular
accuracy or, for example, if the connection cables are long.