11 

2.Installation 
2.5 Electric connections 

 

 

Remote control panel mounting 

 

The remote control panel has the following dimensions: 
width 12 cm   

height 8 cm. 

It can be embedded installed on any boat covering panel, on condition that the area behind is free 
of humidity and condense and there is enough depth to house the rear part of the panel (approx. 8 
cm.). 
Even the computer connecting cable need to run through boat areas not subject to water deposits 
(avoid for example to lay the cable through the bilge). 
 
The cut to be performed on the boat covering panel, to encase the remote control panel, has the 
following dimensions: 
width 9 cm 

 

height 5 cm. 

The control panel, once installed, shall be fixed by Parker type screws. 
 

 

Computer-to-plant wiring

  

The  electric  connectors  are  positioned  inside  the  small  electric  box  connected  to  the  computer 
box.  The  power  supply,  coming  from  the  service  batteries,  needs  to  be  connected  to  the  
terminals  –  and  +  .  The  connection  to  the  boat  panel  needs  to  be  performed  downstream  the 
voltmeter and the ammeter of the boat panelboard. The connecting terminal must be suitable to 
support the plant electric load (approx. 150 Watt). A 15A automatic circuit breaker (for 12VDC 
systems) must be installed on the power supply ,  and 10A (for 24VDC systems). 

The pumps need to be connected to – 12 , the washing electrovalve must be connected to clamps 
– 10, and the pressure switch to  5.  
 
The characteristics of the electric material are:  
 
Automatic  circuit  breakers:  automatic  breakers,  with  16  amp.  cutoff  current  (for  12  Volts 
plants), and 10 amp.   (for 24 Volts plants).  
 
Electric cable: red/black single-pole cable, flame-retardant type sea wiring. The cable section is 
function of the line length and of the feeding type (12 or 24 Volts).  
To  calculate  the  line  length  it  is  necessary  to  add  the positive and negative cable runs. Use the 
following  table  once  determined  these  parameters.  Choose  a  bigger  cable  section  in  case  of 
doubt. 
 

  Voltage 

Automatic 

  

  

Cable lenght  

  

  

  

switch 

         up to 3 mts 

            3 - 7 mt. 

           7-10 mt. 

Volt 

Ampere 

mm2 

  AVG 

mm2 

  AVG 

mm2 

  AVG 

12 

16 

11 

10 

16 

24 

10 

2,5 

13 

11 

11 

Electric cables and switches selection table. 

Содержание MODULAR 30 Electron

Страница 1: ...ponents mounting 2 3 Water intake 2 4 Hydraulic connections 2 5 Electric connections 3 Operating procedures 3 1 By pass activation 3 2 First start up procedure 3 3 Normal operating procedure 4 Mainten...

Страница 2: ...Y RECOVERY SYSTEM which amplifies the pressure of common low pressure pumps and recoups all the hydraulic energy back from the membrane This saves on the use of power allowing the Modular 60 to be run...

Страница 3: ...weight 7 Kg Connections Seawater intake holder for hose int diam 16 mm Salt water outlet holder for hose int diam 16 mm Filter 5 micron polyestere pleated type Power supply 12 Vdc 20 version 30M12 24...

Страница 4: ...normal circumstances as the unit has been pre calibrated at the factory Before changing the settings please call a Schenker Service Point The grey box contains the power relays that activate the pump...

Страница 5: ...roduced fresh water coming out of the unit This is only indicative as the accuracy of the flowmeter is 20 Depressurization valve Is used only during the air bleeding phase at the first plant start up...

Страница 6: ...de the electronics and allow to run the system manually Pressure switch probe It is a little steel device mounted on the aluminum structure It is connected to the computer throw the cables 5 Its funct...

Страница 7: ...lly on a suitable base strong enough to support its weight when the filter housing is full of water It may be necessary to create a suitable wooden or fiberglass structure for the unit if an existing...

Страница 8: ...must be secured with double hose clamps It is not advisable to Tee into the engine cooling water intake as it may impair the cooling of the engine An easily inspected mesh type filter will be require...

Страница 9: ...einforced hose An inadequate hose could burst jeopardizing seriously the safety of the boat The hydraulic connections are Low pressure max 3 bar connections sea water inlet net filter backflow valve i...

Страница 10: ...rantee a water head PRODUCTION FRESH WATER CONNECTION The connection has to be made using the small hose supplied with the equipment The connection has to be made between the polyethylene pipe that co...

Страница 11: ...t panel needs to be performed downstream the voltmeter and the ammeter of the boat panelboard The connecting terminal must be suitable to support the plant electric load approx 150 Watt A 15A automati...

Страница 12: ...ive battery see table pump see table 12 pump see table electrovalve on the AC filter 2 5 mm2 10 electrovalve on the AC filter 2 5 mm2 pressure switch on the watermaker 2 5 mm2 5 pressure switch on the...

Страница 13: ...h the by pass is necessary only in the following two circumstances Plant first start up or plant restart after maintenance operations The use of the bypass is required at start up when purging air fro...

Страница 14: ...he air from the filter 3 Leave both selectors PUMP1 and AUT WASHING not selected vertical lever 4 Push the push button MAN WASH Now the electrovalve opens filling with fresh water the pump head After...

Страница 15: ...c washing procedure uses about 5 litres of water If the unit is in use daily it is not necessary to carry out this procedure every time water is produced As long as the watermaker membrane is cleaned...

Страница 16: ...resh water consumption during this washing cycle is approx 5 litre min 1 Turn on the pressure water system 2 Prearrange the pump turning the PUMP1 selector clockwise 3 Do not prearrange the automatic...

Страница 17: ...T PROCEDURE 1 Turn the system off 2 Open the reset valve lever in horizontal position 3 Screw the positioner knob clockwise until it can be moved no further 10 turns at least are necessary 4 Unscrew t...

Страница 18: ...and mix carefully following the indications on the pack Wear a protection mask in order to avoid inhaling product dusts The water temperature doesn t have to be lower than 25 C preferably Disconnect...

Страница 19: ...ter holder Active carbon filter replacement Every 6 months Purge periodically the air from the system opening at 45 for a couple of minutes the depressurization valve Every 15 days Check the pressure...

Страница 20: ...ng the pump momentarily shuts down Pump pressure switch is not calibrated Dirty filter or membranes Calibrate pressure switch Clean or replace High pressure heads during commutation 0 2 Bar Accumulato...

Страница 21: ...the system still doesn t start check all electric wiring electrical connections box pre wired cable remote panel for fault Replace as required When pressing START the system starts but shuts down afte...

Страница 22: ...ot locate near the pumps unit in areas that can reach elevated temperature Ie Engine compartments or where inflammable substances are stored This will adversely affect the working of the pumps and may...

Страница 23: ...cessories are guaranteed 12 months from delivery The guarantee does not include consumable items filters carbon filters membranes etc The ERS pressure amplification device is guaranteed 36 months prov...

Отзывы: