Replace system controller field fix.
Malfunction of the coil driver.
Replace coil.
Solenoid coil is open or shorted internally.
Check 15 amp fuse on main harness, wiring on all
hydraulic valve coils, repair or replace. Check for
B+ at J4 Pin 3.
If error codes 29-42 occur at the same time; 15
Amp fuse in main harness is bad.
Check and repair damaged wires to the coil.
Broken or shorted wiring to the coil.
PERFORM OUTPUT TEST 07 - TILT BACK SOLENOID.
Solution
Possible Cause
The tilt reverse valve solenoid coil circuit is
overheated, shorted to supply, shorted to ground, or
disconnected.
LIFT system shutdown.
Criteria
Resulting Effect
TILT REVERSE VALVE WIRING FAULT
Fault condition
E34
E34
Replace system controller field fix.
Malfunction of the coil driver.
Replace coil.
Solenoid coil is open or shorted internally.
Check 15 amp fuse on main harness, wiring on all
hydraulic valve coils, repair or replace. Check for
B+ at J4 Pin 3.
If error codes 29-42 occur at the same time; 15
Amp fuse in main harness is bad.
Check and repair damaged wires to the coil.
Broken or shorted wiring to the coil.
PERFORM OUTPUT TEST 08 - SIDESHIFT LEFT SOLENOID.
Solution
Possible Cause
The sideshift left valve solenoid coil circuit is
overheated, shorted to supply, shorted to ground, or
disconnected.
LIFT system shutdown.
Criteria
Resulting Effect
SIDESHIFT LEFT VALVE WIRING FAULT
Fault condition
E35
E35
E
lectric
C
ounterbalance
H
igh
O
utput
Troubleshooting
REV 12/5/99
TS.9