3.
Disconnect the 2-pin connectors from the
horn and from the main harness.
4.
Remove the two screws securing the horn
relay to the frame.
Replacement
1.
Install the horn relay with two screws.
2.
Connect the 2-pin connectors to the horn and
the main harness.
3.
Install the top cover (refer to TOP COVER
Replacement procedure in the FRAME
section).
4.
Connect the battery.
AMPLIFIER DIODES
Special Tools:
Digital Volt-Ohm Meter (DVOM)
with diode test function.
Test for both forward and reverse bias at room
temperature and at 180° F following the diode
test instructions in the meter manual.
E
lectric
C
ounterbalance
H
igh
O
utput
Electrical
4/3/00
8.6