Replace system controller field fix.
Malfunction of the horn driver.
Replace horn.
Horn is open or shorted internally.
Check 15 amp fuse on main harness, wiring on all
hydraulic valve coils, repair or replace. Check for
B+ at J4 Pin 3.
If error codes 29-42 occur at the same time; 15
Amp fuse in main harness is bad.
Check and repair damaged wires to the horn.
Broken or shorted wiring to the horn.
PERFORM OUTPUT TEST 15 - HORN.
Solution
Possible Cause
The horn circuit is overheated, shorted to supply,
shorted to ground, or disconnected.
DISPLAY code.
Criteria
Resulting Effect
HORN WIRING FAULT
Fault condition
E32
E32
Replace system controller field fix.
Malfunction of the coil driver.
Replace coil.
Solenoid coil is open or shorted internally.
Check 15 amp fuse on main harness, wiring on all
hydraulic valve coils, repair or replace. Check for
B+ at J4 Pin 3.
If error codes 29-42 occur at the same time; 15
Amp fuse in main harness is bad.
Check and repair damaged wires to the coil.
Broken or shorted wiring to the coil.
PERFORM OUTPUT TEST 06 - TILT FORWARD SOLENOID.
Solution
Possible Cause
The tilt forward valve solenoid coil circuit is
overheated, shorted to supply, shorted to ground, or
disconnected.
LIFT system shutdown.
Criteria
Resulting Effect
TILT FORWARD VALVE WIRING FAULT
Fault condition
E33
E33
E
lectric
C
ounterbalance
H
igh
O
utput
Troubleshooting
REV 12/5/99
TS.8