2. Install the contactor-fuse panel assembly to
the frame.
3. Install the bus bar between the contactor and
the lift (600 amp) fuse.
4. Connect the power cables to the fuses,
starting with the lowest fuse.
5. Connect the wires to the main power
contactor in the correct locations noted during
Step 5 of Removal.
6. Connect the B+ and capacitor bank supply
cables to the contactor bus bar.
7. Install the top cover (refer to TOP COVER
Replacement procedure in the FRAME
section).
8. Connect the battery.
LIFT AND STEER CONTACTORS
Removal
1.
Disconnect the battery and discharge the
capacitors (refer to CAPACITOR
DISCHARGE Procedure in this section).
2.
Remove the top cover (refer to TOP COVER
Removal procedure in the Frame section).
3.
Label and disconnect the power cables and
wires from the contactor bus bars and coil.
Use a backup wrench to prevent bending the
bus bars.
4.
Remove the screws securing the contactor to
the top plate. Remove the contactor.
Replacement
1.
Align contactor with mounting holes in top
plate. Install screws and tighten.
2.
Connect power cables and wires to contactor
in correct locations as noted in Step 3 of
Removal.
3.
Install top cover (refer to TOP COVER
Replacement procedure in the Frame
section).
4.
Connect the battery.
FUSES
Removal
1.
Disconnect the battery and discharge the
capacitors (refer to CAPACITOR
DISCHARGE procedure in this section).
2.
Remove the top cover (refer to TOP COVER
Removal procedure in the FRAME section).
3.
Remove fuse.
Replacement
1.
Install the proper fuse and tighten the screws.
2.
Install the top cover (refer to TOP COVER
Replacement procedure in the FRAME
section).
3.
Connect the battery.
HORN
Removal
1.
Disconnect the battery.
2.
Remove the top cover (refer to TOP COVER
Removal procedure in the FRAME section).
3.
Disconnect the 2-pin connector.
4.
Remove the two screws securing the horn to
the frame.
Replacement
1.
Install the horn with two screws.
2.
Connect the 2-pin connector.
3.
Install the top cover (refer to TOP COVER
Replacement procedure in the FRAME
section).
4.
Connect the battery.
HORN RELAY
Removal
1.
Disconnect the battery.
2.
Remove the top cover (refer to TOP COVER
Removal procedure in the FRAME section).
E
lectric
C
ounterbalance
H
igh
O
utput
Electrical
4/3/00
8.5