The saw is still in Bypass Mode until
the blade comes to a complete stop!
The saw returns to Normal Mode
automatically after the blade stops .
1
1
1A
1B
Use Bypass Mode to see if material is
conductive and would cause the brake to
activate. Start the saw in Bypass Mode (
see
page 50
), and then carefully make several
cuts on a scrap piece of the material.
The status code (combination of lights)
shown here indicates material is conductive
and must be cut in Bypass Mode to prevent
brake from activating. If this status code is
not displayed after several trial runs, then it is
likely the material is not conductive and you
can make future cuts in Normal Mode.
Push paddle in to stop blade. Green status
light flashes fast while blade spins down.
Saw exits Bypass Mode automatically after
blade stops. After all cuts are completed,
switch power off.
Pull bypass switch out (1A) then remove the
Bypass Key (1B) to disable bypass. Insert
Bypass Key to re-enable.
How Disable Bypass Mode
How to Test Material Conductivity
STOP IN BYPASS MODE
SawStop
®
Jobsite Saw Pro
|
51
Содержание JSS-120A60
Страница 1: ......
Страница 98: ...This page is intentionally blank...
Страница 99: ...This page is intentionally blank...
Страница 100: ...M JSSP 19 0001 00 September 2019...