SAV 876.17
4 ELECTRICAL INSTALLATION AND INTERFACES
Pin
Designation
Type
Level L
Level H
Max.
current
Activity
level
galvanical-
ly isolated
Description
LED
27 In 0
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
28 In 4
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
29 In 1
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
30 In 5
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
31 In 2
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
32 In 6
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
33 In 3
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
34 In 7
IN
0VDC-1VDC
24VDC ±10%
n.a.
n.a.
Yes
Input for selecting the user setup
35 Accept command
IN
0VDC-1VDC
24VDC ±10%
n.a.
H
Yes
H impulse 0.5 s < t < 2.5 s for adopting the
value active on In 0-7 (P27-P34)
36 Acknowledge
OUT 0VDC-1VDC
24VDC ±10%
10mA
H
Yes
Confirm command for selection command H
impulse (3 s < t < 4 s)
37 ENABLE
RELAY 1 (13)
OUT n.a.
max. 24VDC ±10% 100mA NO contact
closed
Yes
Floating relay contact, enable if
NO contact closed
8
38 ENABLE
RELAY 2 (23)
OUT n.a.
max. 24VDC ±10% 100mA NO contact
closed
Yes
Floating relay contact, enable if
NO contact closed
8
39 ENABLE
RELAY 1 (14)
OUT n.a.
max. 24VDC ±10% 100mA NO contact
closed
Yes
Floating relay contact, enable if
NO contact closed
8
40 ENABLE
RELAY 2 (24)
OUT n.a.
max. 24VDC ±10% 100mA NO contact
closed
Yes
Floating relay contact, enable if
NO contact closed
8