4 ELECTRICAL INSTALLATION AND INTERFACES
ATTENTION!
Risk of damage to the device!
If the maximum current of 100 mA is not observed or exceeded, the internal
power supply may be damaged. The device will then no longer function.
■
Pin 2 (24 V DC OUT) and pin 4 (0 V OUT) are only to be used for
supplying the approved accessories.
■
If the approved accessories are connected, no additional devices with
own power supply unit may be connected.
Only the supplied connector is permitted for use as a mating connector; it is shown in the following figure:
Phoenix Contact - DFMC 1.5/20-ST-3.5-LR - 1790661
Figure 7: Mating connector of the control interface
The terminals are rate for cables from 0.25 mm² to 1.5 mm². Rigid and flexible conductors can be used.
We recommend using wire end ferrules without plastic sleeve.