Version 1.0
[
109
]
SAV 876.17
EN
9 APPENDIX
9.2
Type plate
The type plate on the control unit contains a table which shows the different combinations of supply voltage for
the control unit the connected magnet.
The device can supply the connected magnets with 180 V, 210 V or 360 V. The device can also be supplied with
AC – 200 V AC – 230 V AC or 400 V AC. As the device cannot generate a voltage increase at the magnet output,
though, the coil voltages of U
mag
= 180 V, U
mag
= 210 V and U
mag
= 360 V result from the supply voltages minus
approx. 20 V in each case.
This results in three columns for configuration
Ep
from the supply voltage and the associated current for the magnets
assigned to the supply voltage.
Line 4 of the table configuration,
EpSo
, contains a special type of actuation. There is an option of operating mag-
nets with 210 V coil voltage, with a supply voltage for the control unit of 400 V AC.
The factory configuration of the control unit is indicated on the type plate by a cross in the last column of the type
plate table.
Explanation of the abbreviations on the
type plate
Abbre-
viation
Designation
Art-Nr.
Article number
SN
Serial number
Umag
Magnet voltage
Imax
Maximum voltage
Uin
Supply voltage of the [SAV]
CONTROL UNIT
Column for marking the factory configuration of the
control unit
Figure 10 – Type plate