Version 1.0
[
99
]
SAV 876.17
EN
5 OPERATING THE DEVICE
5.2.3
Configuration
Menu
level 1
Menu
level 2
Menu
level 3
Values
Description
Stan-
dard
value
Recommendation
Setup
“Setup” contains all settings which re-
fer to magnetising and demagnetising.
The control interface (see 4.5 Control
interface) can be used to dynamically
switch between the setups.
-
Setup used
0-99
Settings of the setup used
-
Permanent
Set up the predefined curves for mag-
netising and demagnetising
-
Demag. level 0-15
Use the demagnetising level to select
the basic curve for demagnetising
9
- for type SAV 243.77 / .79
0, 1 or 2
- for magnets < 800x400 or
< D1000
9 or 10
- for magnets > 800x400 or
> D1000
8 or 11
Demag. level
fine
0-15
Fine adjustment for the demagnetising
curve
8
Fine adjustment only using a Tesla
meter/the last demagnetising im-
pulses are increased or decreased
Hold. force
curve
0-15
Select the curve for the 16 holding
force levels
1
- for type SAV 243.77 / .79
2 or 3
- others depending on application
No. of
impulses
1-3
Select the number of impulse packages
for magnetising
1
Increase to 2 for large air gaps or
difficult workpieces
Impulse
duration
8-99
Number of impulses in the impulse
package. An impulse is always ½
period of the mains frequency
48
Increase to 54 for large air gaps or
difficult workpieces
Min. hold.
force level
1-16
The minimum holding force level indi-
cates from which holding force level
enable has to be issued after successful
clamping
5
Check depending on application;
milling and turning always with
enable at full holding force
HF calibr.
yes
no
After setting the demagnetising and
magnetising curves as well as the
minimum holding force, a holding
force calibration has to be carried out
with an empty magnet (Calibration
= clamping process and releasing
process)
-
-
Individual
Individually adapt the magnetising and
demagnetising curves selected under
“Permanent”
-
-
Hold. force
curve
0-99
Individually adapt the 16-level holding
force curve
-
-
Red. HF
0-99
Modify the values for reduction
-
-
Demag.
curve
0-99
Adapt the demagnetising curve
-
-
D. imp. time
0-255
The impulse times pertaining to the
demag. curve
-
-