9 APPENDIX
9. APPENDIX
The safety information from item 2 Safety must be observed.
9.1
Technical data and environmental conditions
9.1.1
Dimensions and weight
Width (housing/with clamps)
110 mm / 135 mm
Height (basic device/overall)
185 mm / 220 mm
Depth
200 mm
Weight
4000 g
9.1.2
Electric characteristics
Supply voltage
200 VAC ±10%, 50 Hz/60 Hz
230 VAC ±10%, 50 Hz/60 Hz
400 VAC ±10%, 50 Hz/60 Hz
Output voltage on the magnet con-
nection
180 VDC ±10 %
210 VDC ±10 %
360 VDC ±10 %
Max. power consumption
30 A, impulse
Voltage on the control interface
24 VDC ±10 %
9.1.3
Information regarding DIN EN ISO 13849-1
The control unit was designed based on the rules of functional safety as per DIN EN ISO 13849-1,
with the following features:
■
architecture, logic, safety features as per category 2
■
performance level 2
■
the MTTFd of the safety blocks is 30.45 years.
Conditions for use and environment
WARNING!
Risk of electric shock or destruction of the device!
Failure to protect the device and comply with regulations results in a risk of
electric shock or destruction of the device.
■
To prevent safety hazards for device and operators, the control unit has
to be reliably protected against splash water, steam, vapours, dust and
chips/swarf.
■
The device is intended for installation in an IP54 control cabinet.
■
The relevant regulations must be observed.
The devices are designed for air cooling. The cooling air flow must not be obstructed.