24 GPRS-T6
SATEL
during 15 minutes after module start from any telephone. After receipt of the SMS
programming message, the programming mode will be extended each time by 15 minutes,
counting from the moment of receiving the message.
Using the SMS messages you can:
1. Add phone numbers to the "Telephone numbers for messaging and test transmissions" list
(“GSM telephone, Monitoring stations” tab in the GPRS-Soft program) by sending:
“
SET1=+48XXXXXXXXX=
” - to add the phone number T1,
“
SET2=+48XXXXXXXXX=
” - to add the phone number T2,
“
SET3=+48XXXXXXXXX=
” - to add the phone number T3,
“
SET4=+48XXXXXXXXX=
” - to add the phone number T4,
where the XXXXXXXXX characters denote digits of the number to be added.
2. Delete phone numbers from the "Telephone numbers for messaging and test
transmissions" list by sending:
“
DEL1
” – to delete the phone number T1,
“
DEL2
” – to delete the phone number T2,
“
DEL3
” – to delete the phone number T3,
“
DEL4
” – to delete the phone number T4.
3. Delete all phone numbers from the "Telephone numbers for messaging and test
transmissions" list, sending “
DELALL
”.
4. Reset the number of transmissions sent by the module, sending “
RESET
” (see the “Limit
number of notifications to” parameter, “GSM telephone, Monitoring stations” tab, in the
GPRS-Soft program). Having received this message, the module will start anew the count
of sent transmissions.
The module is case-sensitive, hence the content of SMS messages for programming
the module settings should be entered in upper-case letters.
4.5 Starting GPRS reporting
1. Enter the GPRS communication parameters (“GSM telephone, Monitoring stations” tab):
– Access Point Name (APN) for Internet GPRS connection;
– user name for Internet GPRS connection;
– password for Internet GPRS connection;
– DNS server IP address which is to be used by the module (the DNS server address
requires no programming, if the IP address is entered for the monitoring station).
2. Configure
parameters
of the monitoring station(s) ("GSM telephone, Monitoring stations"
tab):
– select the “GPRS” option;
– enter the monitoring station address (“Address (GPRS)” field);
– enter the number of TCP port through which communication with the monitoring station
will be effected;
– enter the encryption key for data to be sent to the monitoring station (“Station key”);
– enter the GPRS key.
3. Define the protocol to be used by the module for sending event codes to the monitoring
station (“TCP/IP” and “UDP” fields).
4. Determine the operation mode for the inputs, the status of which is to be monitored
(“Inputs” tab):
– define the input type (digital of NO or NC type or analog);