26 GPRS-T6
SATEL
– define additionally the “L threshold”, “H threshold” and “Tolerance” parameters for the
analog inputs.
4. Define which telephone numbers will be notified by using the CLIP service in case of
input status change – fields "T1", "T2", "T3" and "T4" (“CLIP/SMS messaging” tab).
5. Define which telephone numbers and by what kind of SMS messages are to be notified
by the module in case of input status change (“CLIP/SMS messaging” tab):
– select the telephone numbers to which the SMS message about input status change is
to be sent (“T1”, “T2”, “T3” and “T4” fields);
– enter the content of SMS message that will be sent on violating or exceeding
the defined voltage level (“Violation/pass” field);
– enter the content of SMS message that will be sent when the input is restored to its
normal status (“Restore” field).
6. In case of the analog inputs, the “Add input voltage value to message” option can be
additionally enabled (”CLIP/SMS messaging” tab).
5. Initiating the module firmware update by means of SMS
messages
Send an SMS message containing the control command to initiate the process of module
firmware update (“SMS initiating update”, “Firmware update” tab)
to the
module telephone
number. The module will connect to the firmware update server, whose address is
programmed in the module.
If the “Server address in SMS” option is enabled in the module (“Firmware update” tab), you
can send a message with the
xxxx=yyyy:zz=
content, where “xxxx” is the control command,
programmed in the module, which starts the update process, “yyyy” is the address of server
with current firmware for the module (IP address or name), and “zz” is the server port
number. The module will connect to the computer whose address is given in the SMS
message. If the control command in the SMS message is correct, and the other data are
wrong, the address and port of the server to which the module is to connect will be
downloaded from the settings programmed in the module.
After completion of the update, an SMS message with information on the result of update
process and module firmware version will be sent to the telephone number from which the
SMS message initiating the firmware update process was sent.
6. Restoring factory default settings
In order to restore the module factory settings, select the “Communication” command in the
menu bar, and then, in the menu that will be displayed, select the "Factory default settings"
function. A message will be displayed in which you should confirm your intention to restore
the module factory defaults.
Most parameters in the factory default settings are not defined, and the options are not
enabled. Only the following parameters are defined:
“GSM telephone, Monitoring stations” tab
Monitoring station 1 / 2:
Disabled – the field is selected
GPRS reporting
TCP / IP – enabled
SMS format – Event =
,
,
,
,
=