![Satec PM172EH Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/satec/pm172eh-series/pm172eh-series_installation-and-operation-manual_1200381012.webp)
6
Chapter 1 Introduction
Parameter Display Comm. Analog Pulse Alarm
Total Energy
Total Active Energy Import & Export
3
3
#$
Total Reactive Energy Import & Export
3
3
#$
Total Reactive Energy Net
3
Total Apparent Energy
3
3
#$
TOU Registers
7 Energy registers
3
3
3 Maximum demand registers (selectable kW
import & export, kvar import & export, kVA
demands)
3
16 Tariffs for each TOU register
3
Harmonic Measurements
Voltage THD per phase
3
3
#$ $
Current THD per phase
3
3
#$ $
Current TDD per phase
3
3
#$ $
K-factor per phase
3
3
#$ $
Voltage harmonics per phase up to order 40
3
3
Current harmonics per phase up to order 40
3
3
Voltage harmonic angles up to order 40
3
Current harmonic angles up to order 40
3
Total Harmonic Powers
Total Harmonic Active Power
3
3
$
Total Harmonic Apparent Power
3
3
$
Total Harmonic Energy
Total Harmonic Active Energy Import & Export
3
3
Total Harmonic Apparent Energy
3
3
Fundamental
Values
Voltage and Current per phase
3
kW, PF per phase
3
3
kvar, KVA per phase
3
Total kW, PF
3
3
Total kvar, KVA
3
Real-time (RT) Values
RT RMS Voltage per phase
3
#$ $
RT RMS Current per phase
3
#$ $
RT Active Power per phase
3
$
RT Reactive Power per phase
3
$
RT Apparent Power per phase
3
$
RT Power Factor per phase
3
$
RT Total Active Power
3
#$ $
RT Total Reactive Power
3
#$ $
RT Total Apparent Power
3
#$ $
RT Frequency
3
#$ $
RT Neutral Current
3
#$ $
RT Total Power Factor
3
#$ $
RT Voltage & Current unbalance
3
$
Min/Max Logging
Min/Max A, V, total kW, kvar, kVA, PF
3
3
Min/Max Frequency, Neutral current
3
3
Содержание PM172EH Series
Страница 1: ...Series PM172EH Powermeters Installation and Operation Manual BG0361 Rev A2 ...