![Sartorius CAIS1 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/sartorius/cais1/cais1_operating-instructions-manual_1199616073.webp)
A tare value entered manually overwrites a stored tare value (weight value). If you
enter a tare value manually, a tare value (weight value) stored later overwrites the
manually entered value.
Setting:
Applic. / TARE.FNC
menu item 3.25.2
Restore factory default settings:
Applic./Reset
menu item 9.1.
Target
Checkweighing entails comparing the current weight value to a defined target. You
can enter the value for this target using the keypad, or by saving the weight value
indicated. You can also define upper and lower tolerance limits based on this target.
You can do this by:
– Entering absolute values using the keypad or placing the desired amount of
weight on the platform and saving the value
or
– by entering each value as a percentage deviation of the target weight
or
– by entering each value as an asymmetrical percentage deviation of the target
weight that is selected via the keypad or using the
r
key
or
– by entering a relative weight deviation from the target weight via the keypad.
The value remains valid until deleted by pressing the
c
key or until overwritten by
a new value. It remains saved after the scale is switched off.
Preparation
t
Open the
APPLIC. / APPLIC.2 / CHECK.WG
menu.
Available parameter settings
* = Factory setting
MIN.INIT
Minimum load for initialization
3.5
1 digit
1 digit
3.5.1*
2 digit
2 digits
3.5.2
5 digit
5 digits
3.5.3
10 digT.
10 digits
3.5.4
20 digT.
20 digits
3.5.5
50 digT.
50 digits
3.5.6
100 diG.
100 digits
3.5.7
200 diG.
200 digits
3.5.8
500 diG.
500 digits
3.5.9
1000 dI.
1000 digits
3.5.10
Aut.strt
Automatic start of applications when you switch on
the device with most recently saved application data
3.8
automat
Automatic (on)
3.8.1*
manual
Manual (off)
3.8.2
TARE.FNC
Tare function
3.25
normal
Can add a preset tare if tare value is avail-
able; however no tare function possible
3.25.1*
special
When a preset tare is entered, the tare
value is deleted; however, tare function
activation is possible
3.25.2
CHECK.RG
Checkweighing range
4.2.
30- 170%
30 to 170%
4.2.1*
10-max.l
10% to infinity
4.2.2
Operating Instructions Combics Indicators
73
Operation
Содержание CAIS1
Страница 126: ...126 Operating Instructions Combics Indicators Declarations of Conformity Declaration of Conformity...
Страница 127: ...Operating Instructions Combics Indicators 127 Declarations of Conformity...
Страница 128: ...128 Operating Instructions Combics Indicators Declarations of Conformity...
Страница 129: ...Operating Instructions Combics Indicators 129 Declarations of Conformity...
Страница 130: ...130 Operating Instructions Combics Indicators Test Certificate...
Страница 131: ...Operating Instructions Combics Indicators 131 Plates and Markings...
Страница 132: ...132 Operating Instructions Combics Indicators Plates and Markings...
Страница 133: ...Operating Instructions Combics Indicators 133 Plates and Markings...
Страница 134: ...134 Operating Instructions Combics Indicators Plates and Markings...
Страница 155: ...Operating Instructions Combics Indicators 155 Appendix Guide to verification...
Страница 158: ...158 Operating Instructions Combics Indicators...
Страница 159: ...Operating Instructions Combics Indicators 159...