48
The Sapling Company, Inc.
1633 Republic Road
Huntingdon Valley, PA 19006
USA
P. (+1) 215.322.6063
F. (+1) 215.322.8498
www.sapling-inc.com
Manual Controls
The numbers shown on the left are examples. Going down the list and entering every one of
the examples exactly as shown will cause the master clock to malfunction or use incorrect data.
Program your clock setting based off of the instructions in the description on the right.
The settings below only apply to Sapling analog clocks using wired communication protocols such as
2-Wire Digital or RS485. The digital clock cannot send these commands to Wireless, IP or Wi-Fi clocks.
Setting 40 - Command Analog Clock to Perform Diagnostic
Allows the user to send a command to all analog clocks receiving data from
this digital clock. The available commands are the diagnostic tests listed in the
table below:
01 - Diagnostic 1 -
Protocol Verification
03 - Diagnostic 3 - Resets clock to
Manufacturing Default and sets
all hands to 12
05 - Diagnostic 4 - Full
Mechanical and Electrical Test.
Begins automatically.
02 - Diagnostic 2 -
Comprehensive Test
04 - Diagnostic 4 - Full
Mechanical and Electrical Test.
Press button on analog to start.
09 - Override diagnostic tests and
return analog clocks to showing
master clock time.
d - Does not send a command
Details on the function of each diagnostic test can be found in the analog
clock manual.
Setting 41 - Diagnostic Results Display Duration
This setting determines how long the results of a diagnostic test will remain
on the face of an analog clock. Due to the nature of the tests, this time period
only applies if values 01 or 02 were selected for Setting 40.
Press the bottom button to scroll from 00 to 99. For example, a value of 98 will
set a display duration of 1 minute and 38 seconds.
Pressing the top button after Setting 41 will cause the clock to return to the normal time display.
40
--
d
41
-
60