46
The Sapling Company, Inc.
1633 Republic Road
Huntingdon Valley, PA 19006
USA
P. (+1) 215.322.6063
F. (+1) 215.322.8498
www.sapling-inc.com
Manual Controls - Technician Level
Setting the Time Zone Offset
1) Use the keypad to enter the technician password (the default is 6063). If performed correctly, the LCD
screen should change to show the “Set Pri Time Source” message:.
2) Press the NO/CANCEL button until the LCD screen display shows the following text:
Set TimeZone Offset?
3) Press and release the YES/ENTER button. The LCD screen will display the following text:
Time Zone -05 Hours
4) Use the keypad to enter a number between from 00 through 12. Use the Up ( ) and Down ( ) Arrow
keys to scroll between positive and negative offset.
5) Press the YES/ENTER key to confirm the selection.
6) When you are finished, repeatedly press the NO/CANCEL button until the main screen reappears.
Setting the IP Address
1) Use the keypad to enter the technician password (the default is 6063). If performed correctly, the LCD
screen should change to show the “Set Pri Time Source” message.
2) Press the NO/CANCEL button until the LCD screen display shows the following text:
Set IP Address?
3) Press and release the YES/ENTER button. The LCD screen should display four groups of three digits,
separated by dots.
(Example: 192.168.000.005)
4) Use the keypad to enter a new twelve digit IP address. Write a copy of the new IP address in your
personal record.
a) For a static IP address, enter an IP address that fits within your IP scope. Consult your network
administrator for more information.
b) To automatically obtain an IP address from a DHCP server, enter the value 000.000.000.000
5) Press the YES/ENTER key to confirm the new IP address.
6) When you are finished, repeatedly press the NO/CANCEL button until the main screen reappears.
7) Power cycle the clock to apply the new IP address.
<-
-
<-
-