31
The Sapling Company, Inc.
1633 Republic Road
Huntingdon Valley, PA 19006
USA
P. (+1) 215.322.6063
F. (+1) 215.322.8498
www.sapling-inc.com
The function of this section is to quickly configure a new master clock by using the master clock’s web
interface. This instruction set covers NTP and GPS time sources only. For a full list of features available
through the web interface, please see the section labeled
Web Interface-Log In
. If you are unable to
program the master clock through the web interface, go to the section labeled “Manual Controls” for an
alternative programming method. This section continues from “Basic Configuration--DHCP and Static IP.”
Please complete that section first.
NOTE:
Firewall Ports 80 (TCP), 123 (NTP), and 1777 (TCP/UDP) must be open to use the master clock on a network.
1) Access the web interface on a web browser (such as Internet Explorer) by entering the master clock IP
address into your browsers address bar. The IP address can be viewed by pressing and releasing the 1 and
9 buttons on the master clock front panel simultaneously. The LCD screen will automatically switch back to
displaying the time after four seconds have passed.
2) Enter the password for the web interface. It should be
6063
. Do not use the keyboard number pad.
To submit the password, use your mouse or touchpad to press the Log In button. Pressing the enter/
return key on your keyboard does not submit the password. If the password does not work, contact
tech support.