SANY LATIN AMERICA
4-191
SY195/205/215/225C9 Crawler Hydraulic Excavator
Structure and Function
Shop Manual - June 2013
Function
●
Set the maximum engine speed under
each working mode. This set speed is the
standard to control engine speed.
Operation
●
Calibrating procedure for positive
fl
ow exca-
vators.
1) Selection of fixing point of throttle motor
soft shaft
2) H, S, L maximum speed calibration, and A/
I speed calibration.
3) Turn the dial on the calibrator counter-
clockwise to the end
4) Power OFF
5) Set the calibrator to "Monitor mode", power
on and check the result.
Remark:
Memory SW up: Calibration mode;
Memory SW down: Monitor mode
For more information, see “Engine Speed -
Test and Calibrate” on page 6-3.