SANY LATIN AMERICA
1-13
SY195/205/215/225C9 Crawler Hydraulic Excavator
Introduction
Shop Manual - June 2013
4) Drying wiring harness
If there is any oil or dirt on the wiring
harness, wipe it off with a dry cloth. Avoid
washing it in water or using steam. If the
connector must be washed in water, do not
use high-pressure water or steam directly
on the wiring harness. If water gets directly
on the connector, do as follows.
a. Disconnect the connector and wipe off
the water with a dry cloth.
NOTE: If the connector is blown dry
with compressed air, there is the risk
that oil in the air may cause defective
contact, so remove all oil and water
from the compressed air before blowing
with air.
b. Dry the connector with a dryer.
If water gets inside the connector, use
a dryer to dry the connector.
NOTE: Hot air from the dryer can be
used, but regulate the time that the
hot air is used in order not to make the
connector or related parts too hot, as
this will cause deformation or damage
to the connector.
c. Carry out a continuity test on the con-
nector.
After drying, leave the wiring harness
disconnected and carry out a continuity
test to check for any short circuits be-
tween pins caused by water.
NOTE: After completely drying the con-
nector, blow it with contact restorer and
reassemble.
ZX215-1000018
T adapter
ZX215-1000017
ZX215-1000009
https://www.tractormanualpdf.info/