Improper installation of expansion valve/thermal pipe defect (wide opening)
Symptom: insuf
fi
cient refrigeration
Symptom
Cause
Analysis
Remedy
●
Pressure at both
Hi- and Lo-pressure
ends very high
●
Frosting or conden-
sation on Lo-pres-
sure piping
●
Expansion valve de-
fect, or improper instal-
lation of thermal pipe
●
Over-
fi
lling of
refrigerant in
Lo-pressure
piping
●
Expansion
valve opening
very wide
●
Check the installation of
thermal piping
●
If thermal piping is normal,
check the expansion valve.
Replace defective expan-
sion valve if observed.