4) High-pressure water entering connector
The connector is designed to make it
difficult for water to enter (drip-proof
structure), but if high-pressure water is
sprayed directly on the connector, water
may enter the connector, depending on the
direction of the water jet. Accordingly, take
care not splash water over the connector.
The connector is designed to prevent
water from entering, but at the same time,
if water does enter, it is difficult for it to
be drained. Therefore, if water should get
into the connector, the pins will be short-
circuited by the water, so if any water gets
in, immediately dry the connector or take
other appropriate action before passing
electricity through it.
ZX215-1000008
5) Oil or dirt stuck to connector
If oil or grease are stuck to the connector
and an oil film is formed on the mating
surface between the male and female pins,
the oil will not let the electricity pass, so
there will be defective contact. If there is
oil or grease stuck to the connector, wipe
it off with a dry cloth or blow it dry with
compressed air and spray it with a contact
restorer.
NOTE:
●
When wiping the mating portion of the
connector, be careful not to use exces-
sive force or deform the pins.
●
If there is oil or water in the com-
pressed air, the contacts will become
even dirtier, so remove the oil and wa-
ter from the compressed air completely
before cleaning with compressed air.
ZX215-1000009
https://www.tractormanualpdf.info/