Use and maintenance instructions
CAFE’ RACER
GB
36
17 -
TROUBLESHOOTING
Below is a list of faults and malfunctions which could arise while using the machine.
For all problems not included in this table, contact technical assistance.
PROBLEM
CAUSES
REMEDY
The boiler fill level display
flashes
The mains water or purifying filter
taps are closed
Open the tap
Boiler fill malfunction
Turn off power for at least 5
seconds, then turn on again by
pressing the ON\OFF button
Call technical assistance
No water is delivered from the
group
The mains water or purifying filter
taps are closed
Open the tap
The filter on the water intake
coupling is clogged
Remove and clean
Check regeneration of the water
purifying filter
Clogged gigleur
Call technical assistance
The water does not heat up
Heating element burnt out
Call technical assistance
Temperature sensor malfunction
Call technical assistance
Continuous water fill (the water
level flashes on the display)
Faulty level sensor
Call technical assistance
The doses delivered are not
regular
Faulty volumetric doser
Call technical assistance
The ground coffee is too fine or
too coarse
Check grinding time and/or
adjust grinding coarseness
Shower screen and filters
partially clogged
Call technical assistance
Insufficient coffee is used
The steam wand leaks with the
tap closed
Faulty gasket
Call technical assistance
Steam leaks from under the tap
knob when open
Faulty tap spindle seal
Call technical assistance