29
4.
VoL (Volume Setting)
・
Display by Operation Procedure 1 and 2. Push
④
the “Enter Button” to select.
・
Turn
⑤
“Dial”. Select the number (Chart-3) you want to change, then push
④
the “Enter
Button”. The timer of the selected Volume Setting shows up.
・
Change the timer by turning
⑤
the “Dial”. Set the timer by pushing
④
the “Enter Button”
once again.
Chart-3
“Volume Setting” List
No. Setting
Default Setting
V 1
The time of both steam injection and blower while working
simultaneously in automatic mode
2.0sec.(Max 6.0sec)
V 2
The time from Rotation Middle Sensor (SQ02) turning ON to
switching Solenoid Valve (No. 10 and No. 11)
0.12sec.(Max 1.0sec)
V 3
The time of Shoulder Expander Solenoid Valve being ON after
pressing the Shoulder Pedal
1.0sec.(Max 2.0sec)
V 4
The time of the body going up after Steam Timer is over while in
automatic mode
0.2sec.(Max 1.0sec)
V 5
The time of Side Expander Solenoid Valve (No. 4) from ON to OFF
3.0sec.(Max 5.0sec)
V 6
Pedal reaction time to prevent from chattering of the multi function
pedal.
0.2sec.(Max 0.5sec)
V 7
The time of interval of process to process while in automatic mode
2.0sec.(Max 5.0sec)
5.
diP (DIP Setting)
・
Display by Operation Procedure 1 and 2. Push
④
the “Enter Button” to select.
・
Turn
⑤
the “Dial”. Select the number (Chart-4) you want to change, then push
④
the “Enter
Button”. The selected DIP Setting shows up.
・
Push
④
the "Enter Button". The current setting will show up. Turn
⑤
the "Dial" to change ON
or OFF. Push
④
the "Enter Button" again. The new setting is now saved.
Chart-4
“DIP Setting” List
No.
Setting
Default
Setting
d 1
Select Laundry Button ON (Wet)/Off(Dry)
(Initial Setting) while power being ON
ON
:
Wet Mode
OFF
OFF
:
Dry Mode
d 2
When Wet Mode, select Center Vent or Side
Vent Clamp
ON
:
Both Clamp ON
ON
OFF
:
Only the selected mode ON
d 3
When Dry Mode, select Center Vent or Side
Vent Clamp
ON
:
Both Clamp ON
OFF
OFF
:
Only the selected mode ON
d 4
Select Clamp release and body going down
after automatic mode is over
(Multi function foot pedal or a reset button)
ON
:
They work separately
ON
OFF
:
They work at the same time.
d 5
Select Clamp release and body going down
after automatic mode is over.
(Multi function foot pedal only)
(Reset button is operation of always OFF.)
ON
:
They work at the same time.
ON
OFF
:
They work separately
Содержание DF-100E-V3
Страница 40: ...40 ...
Страница 42: ...42 Front Diagram 1 Front Diagram REV 3 ...
Страница 44: ...44 Rear Diagram 2 Rear Diagram REV 3 ...
Страница 46: ...46 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Страница 48: ...48 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Страница 50: ...50 Steam Piping Diagram 4 Steam Piping Diagram REV 3 ...
Страница 52: ...52 Cover Diagram 5 Cover Diagram REV 3 513 ...
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 61: ......
Страница 62: ...DF 100E V3 Rev 6 2019 1 ...