![Sankosha DF-100E-V3 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/sankosha/df-100e-v3/df-100e-v3_instruction-manual_3977340016.webp)
16
Run the machine where air can be supplied in a stable condition.
Use after-cooler or similar equipment to supply clean air at all times.
Operation Procedures
Provide Air
Check whether air pressure is set at the required
level for main regulator and other regulators as
below.
①
Main Regulator
・・・
0.5MPa
②
Body Rotation Cylinder
・・・
0.3MPa
③
Side Expander Cylinder
・・・
0.2MPa
④
Shoulder Expander Cylinder
・・・
0.2MPa
Body Up/Down Cylinder
Low air pressure can cause a malfunction. If the pressure does not reach its standard level, set the
air pressure properly following the procedure below.
Check Point
Check compressor if the main air pressure does not reach 0.5MPa even after the above adjustment
③
①
②
④
Follow the procedure for proper operation.
Improper operation can cause mechanical failure or injury to operators.
CAUTION
■
How to adjust air pressure
1.
Pull the adjustment knob up.
2.
Turn the knob to adjust air pressure
Clockwise
→
Pressure will increase
Counterclockwise
→
Pressure will decrease
3.
Push the knob down.
Attention!
Содержание DF-100E-V3
Страница 40: ...40 ...
Страница 42: ...42 Front Diagram 1 Front Diagram REV 3 ...
Страница 44: ...44 Rear Diagram 2 Rear Diagram REV 3 ...
Страница 46: ...46 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Страница 48: ...48 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Страница 50: ...50 Steam Piping Diagram 4 Steam Piping Diagram REV 3 ...
Страница 52: ...52 Cover Diagram 5 Cover Diagram REV 3 513 ...
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 61: ......
Страница 62: ...DF 100E V3 Rev 6 2019 1 ...