37
3.
Steam Pressure
:
Figure-3
Check the steam pressure gauges
(
0.5MPa
)
.
※
If the steam pressure does not reach the
required level, it may adversely affect the
garment finishing quality.
4.
Steam trap check
:
Figure-3
Check to see if the Steam Trap works properly.
If not, it may malfunction. If the trap is our
recommended
OVK’s trap, open the cock
and discharge the drain. Close the faucet
after discharge.
5.
Cover check
:
Figure-4
Check to see if it is dirty, torn or not. (Body, front clamp, rear clamp, side clamp, side vent clamp and
lower body cover) Dirt and any type of tear can negatively affect finish quality.
6.
Emergency stop check
:
Figure-4
Push the emergency stop button to ensure that the machine stops.
Emergency Stop
Button
Lower Body Cover
Steam Pressure Gauge
(0.5MPa)
Cock
Body Cover
Front Clamp Cover
Side clamp cover
(2 places)
Rear Clamp Cover
Side Vent Clamp
Cover
(2 places)
Figure-3
Figure-4