4. Installation preparations
56
© Sandvik SRP AB – Doc. no. S 223.510 en Ver. 1
CH420:01
4.4.3
Insulation of the bottom of the component section
of the oil tank unit
The component section of the oil tank unit is normally open at the bottom to
provide good ventilation and cooling of the oil pumps. In the winter it might
be necessary to insulate the tank to keep the oil at working temperature and
prevent pressure drop.
4.4.4
Additional oil heaters
In order to heat the oil to the correct temperature, it can be necessary to
install extra heaters. Installation is easiest if this equipment is ordered
together with a new crusher, but extra heaters can also be fitted in the tanks
of older crushers.
4.4.5
Diesel heating system
In plants without 24-hour electrical power, a timer-controlled diesel heating
system can be used. The system starts heating the oil up to three hours before
electrical power is available.
The tank unit is prepared for diesel heating.
The diesel heating system uses a 12 V DC supply.
Modification kit
Drawing
442.6965-00
1.442.8911
Modification kit
Drawing Voltage
(V)
Rating
(W)
Connection
diagram
984.0607-00 (2 x)
1.442.8911
265/460
240/415
220/380
2 x 1640
2 x 1340
2 x 1125
3.194.0191
Modification kit
Drawing
442.9993-90
1.442.8911
Содержание CH420:01
Страница 1: ...installation manual Doc no S 223 510 SANDVIK CH420 01 ...
Страница 8: ...Table of contents 6 Sandvik SRP AB Doc no S 223 510 en Ver 1 CH420 01 ...
Страница 19: ...1 Introduction 17 CH420 01 Sandvik SRP AB Doc no S 223 510 en Ver 1 This page is intentionally left blank ...
Страница 20: ...1 Introduction 18 Sandvik SRP AB Doc no S 223 510 en Ver 1 CH420 01 ...
Страница 31: ...29 Sandvik SRP AB Doc no S 223 510 en Ver 1 CH420 01 3 Technical data ...
Страница 42: ...3 Technical data 40 Sandvik SRP AB Doc no S 223 510 en Ver 1 CH420 01 This page is intentionally left blank ...
Страница 109: ......
Страница 110: ......