Appendix A: Post-Installation Procedures
82005-IM-K
Sandel SN3500 Installation Manual
Page 7-25
7.1.14
Page 14: BRT/DATA BLK
Configuration Field
Options
Comment
Selection INTERNAL
EXTERNAL
Selects the brightness control to be
external or internal.
P1-26 NONE
Monitors
external brightness bus
voltage. Not shown when brightness
control selection is set to INTERNAL.
Min Brt V Norm
Adjusts the external brightness bus to
the desired night-brightness voltage.
Adjustable from 1.5 volts to 15.0 volts.
Not shown when brightness control
selection is set to INTERNAL.
Min Brt V NVIS
Adjusts the external brightness bus to
the desired NVIS brightness voltage.
Adjustable from 1.5 volts to 15.0 volts.
Not shown when brightness control
selection is set to INTERNAL. Not
applicable to non-NVIS units.
DATA RECORD BLK
None
For factory use.
Calibrating the external brightness control minimum brightness:
BEFORE performing calibration:
Select the “BRT” maintenance page, select EXTERNAL for brightness control.