General Information
82005-IM-K
Sandel SN3500 Installation Manual
Page 1-3
Recommended Crimp Tools
High Density
22-28 AWG
Standard Density
20-24 AWG
Manufacturer
Hand Crimping
Tool
Positioner
Insertion/
Extraction Tool
Positioner
Insertion/
Extraction Tool
Military P/N
M22520/2-01 M22520/2-09 M81969/1-04 M22520/2-08 M81969/1-02
Positronic 9507 9502-3
M81969/1-04 9502-5 M81969/1-02
ITT Cannon
995-0001-584
995-0001-739 N/A 995-0001-604
980-2000-426
AMP 601966-1
601966-6
91067-1
601966-5
91067-2
Daniels AFM8 K42
M24308/18-1 K13-1 M24308/1-02
Astro 615717
615725
M81969/1-02 615724 M81969/1-02
1.3.2
Post Installation Summary
1)
Prior to power-up review correct wiring by using standard ohmmeter and
voltage checks. Insure the correct orientation and positioning of the three
SN3500 ‘D’ connectors. The connector numbers are printed on the back
of the SN3500 for reference.
2)
Review special items such as connection of the NAV receiver resolver
wiring.
3)
Apply power to the SN3500, bring up in maintenance mode and
sequentially access each SN3500 maintenance page to correctly select
the installed equipment.
4)
Perform Ground Test procedures
5)
Perform Flight Test procedures.
1.4
Interface Planning
1.4.1
Compass System
Determine whether the SN3500 is to be used internally slaved or unslaved.
Unslaved operation would be appropriate when the SN3500 is bootstrapped to an
already slaved compass system or is being slaved to a panel mounted DG with
bootstrap output.
Plan for:
High Resolution Digital Output from a Mid-Continent 4305 series DG with
gyro valid output, flux gate 10 Vac Fluxgate Excitation and Internal 26Vac
Inverter (internal slaving)