Installation
82005-IM-K
Sandel SN3500 Installation Manual
Page 3-3
See Installation Wiring Diagrams and the MAINTENANCE MENU,
Configuration Instructions for notes pertaining to these considerations.
H.
Ground Bonding.
In order to assure installation characteristics match the
DO-160 RF and Lightning test conditions, ensure that two ground wires of at
least the recommended size are installed in accordance with the installation
drawings and these wires are connected to a bonded aircraft ground. Ensure
that shielded wiring is used to the Flux Gate (if installed), Gyro Reference, and
Gyro XYZ (if installed).
I.
Power Wiring.
To assure that the SN3500 will operate properly down to its
rated minimum input voltage of 22Vdc, ensure that two power wires of at least
the recommended size are connected from the SN3500 circuit breaker to the
SN3500 in accordance with the installation drawings.