Samsung Programming
SVMi-8 Manual MMCs
MMC: 501
TIMER NAME
DEFAULT
RANGE
RECALL WAIT TIME
15 SEC
1–255 SEC
SMDR START/DP
30 SEC
1–255 SEC
SMDR START/DTMF
15 SEC
1–255 SEC
SYS HOLD RECALL
45 SEC
0–255 SEC
TRANSFER RECALL
20 SEC
0–255 SEC
UCDS AUDIO ALARM*
0 SEC
0–255 SEC
UCDS VISUAL ALARM*
0 SEC
0–255 SEC
VOICE DIAL DELAY
08 SEC
5–15 SEC
R/D RING ON (NOT USED)
–
–
R/D SIGNAL ON (NOT USED)
–
–
PERI UCD REPORT
5 SEC
3–99 SEC
NOTE: Timers marked with an as terisk require optional hardware and/or software.
TIMER DESCRIPTIONS
AA INT DGT TIME
When the AA card is installed, this timer determines the inter-
digit time for AA call processing. If this timer expires before
valid digits are received by the AA card, the call will be routed to
the AA invalid digits destination.
AA NO ACT TIME
When the AA card is installed, this timer determines the time
that the AA card will wait for a first digit for AA call processing. If
this timer expires before a digit is received, the call will be
routed to the AA no action destination.