Transfer Controls
Simultaneous Xfers-Y/N
Set this parameter to 'Y' to allow more than one port to transfer to the same station
simultaneously. This applies to blind transfer conditions only. Station groups and operator positions are examples of
"Yes" situations.
Internal Station
Not used.
Monitor Transfers
Not used.
Message Waiting Indicator Controls
(Remove ) Dial To Set MWI On
Enter the string needed to turn message waiting indicators on . Since the SVMi-8
knows how to do this internally, you would only use these to set MSG lights on remote systems.
(Remove) Dial To Set MWI Off
Enter the string needed to turn message waiting indicators off. Since the SVMi-8
knows how to do this internally, you would only use these to set MSG lights on remote systems.
Call Progress Training
The station block can be used to train the SVMi-8 to recognize different call progress tones (ring back and busy) for
the particular station block. However, this is normally not necessary as default values are already programmed into
the SVMi-8.
Ringing Number
Enter any string returned by the phone system to indicate ring. The second field indicates how
many times the Train routine is to be run, using the number entered in the first field.
Busy Number
Enter any string returned by the phone system to indicate busy. The second field indicates how
many times the Train routine is to be run, using the number entered in the first field.
Retrain - Y/N
Set to 'Y' to preserve the original values. Set to 'N' to clear.
Retrain - Train
To run the Call Progress Train routine, enter a telephone number in either the ringing number field,
the busy number field, or both fields. Specify the number of times SVMi-8 is to try the number to gather data. Press
ENTER to start Call Progress Training. Four conditions apply to the train routine:
If only the Ringing Number value is filled in, only those values which pertain to a ring signal will be modified by
running the Call Progress Train routine.
If only the Busy Number value is filled in, only those values which pertain to a busy signal will be modified by
running the Call Progress Train routine.
If no numbers are provided for Ringing or Busy, and Retrain is set to 'N', the factory default settings are auto-
matically filled in by SVMi-8.
If no numbers are provided for Ringing or Busy, and Retrain is set to 'Y', SVMi-8 will give an error warning.
Block Types and Descriptions