4. Troubleshooting
► Error Code
A3–3312
A3–3320
► Error message
Sensor Failure: #A3-3312. Turn off then on. Call for service if the problem persists
The room temperature is not suitable for this set use. Please adjust room temperature
► Symptom
Outer temperature/humidity sensor is defective.
► Troubleshooting method
1) Enter SVC mode. Execute sensor test to check its operation.
(
Diagnostics > Engine Diagnostics > Engine Test Routines > Outer Temperature
)
2) Measure the resistance value of the connector at both ends.
If the value is not in 47.5KΩ ~ 52.5KΩ (@ 25
℃
), replace the outer temperature/humidity sensor(
JC32-00005A
).
3) If the harness and sensor are normal, replace the main board(
JC92–02722A
).
Copyright© 1995-2013 SAMSUNG. All rights reserved.