4. Troubleshooting
► Error Code
A3–3212
► Error message
Sensor Failure: #A3-3212. Turn off then on. Call for service if the problem persists
► Symptom
Inner temperature sensor is defective.
► Troubleshooting method
1) Enter SVC mode. Execute sensor test to check its operation.
(
Diagnostics > Engine Diagnostics > Engine Test Routines
)
2) Measure the resistance value of the connector at both ends.
If the value is not in 47.5KΩ ~ 52.5KΩ (@ 25
℃
), replace the inner temp sensor(
1404-001417
).
3) If the sensor is normal, replace the main board(
JC92–02722A
).
4-63
Copyright© 1995-2013 SAMSUNG. All rights reserved.
Содержание SL-M4580FX
Страница 31: ...2 Product Specifications and Description Paper Path Copyright 1995 2013 SAMSUNG All rights reserved 2 18 ...
Страница 82: ...3 Disassembly and Reassembly 9 Release the left cover 3 11 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 124: ...4 Troubleshooting 13 Insert the tray 1 4 21 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 239: ...5 System Diagram 5 System Diagram Copyright 1995 2013 SAMSUNG All rights reserved 5 1 ...