Appendix A-11
Stall Prevention
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
P2.01
Stall Prevention
at Start
-
0~1
1
X
5-65
P2.02
Stall Prevention
Level at Start
1%
0~200
170
○
5-65
P2.03
Stall Prevention
at Acc Limit
1%
0~100
50
○
5-66
P2.04
Stall Prevention
at Stop
-
0~1
1
X
5-67
P2.05
Stall Prevention
in Running
-
0~2
1
X
5-68
P2.06
Stall Prevention
Level in Running
1%
0~200
170
○
5-68
Over Torque Detection
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
P3.01
Overtorque
Detection
-
0~4
0
X
5-70
P3.02
Overtorque
Detection Level
1%
0~300
180
○
5-71
P3.03
Overtorque
Delay Time
1sec
0.0~10.0
0.1
X
5-71
Retry Fault
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
P4.01
Number of
Fault Retry
-
0~10
0
X
5-72
P4.02
Output Terminal
Function at Retry
-
0~1
0
X
5-73
Fan Error
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
P5.01
Fan Error
-
0~1
0
X
5-73
A-12
MOSCON-E7 User’s Manual
Appendix C
E7 Dynamic Brake User’s Manual
1. Mounting
For the optimal performance of the dynamic brake, mount it in a place,
which satisfies the conditions listed below.
- Refer to the figure 1 for the dimensions and installation space.
- A dynamic brake and braking resistor generate heat, thus install the
peripheral devices, which are not tolerant to heat, far away from
them.
-
Refer to the figure 1 for the mounting method.
Dynamic Brake
MOSCON-E7
Figure 1. Mounting method
M4 SCREW (2 places
)
96 86
25
35.5
64