5. Parameters
5-51
• Setting
Setting
constant
Function (The contact output
is activated by the definition
specified in H1.02 when the
following situation occurs.)
Description
0 Fault
occurred
1 Running
2
Matching command frequency
Output frequency matches
with command frequency.
U0.01 – F1.09
≤
U0.02
≤
U0.01 + F1.09
3 Matching
temporary
frequency
Output frequency matches
with command frequency of
match detection.
F1.08 – F1.09
≤
U0.02,
U0.02
≤
F1.08 + F1.09
4
Defeated matching frequency
or higher
Output frequency is higher
than the frequency detection
level.
U0.02
≥
F1.08
5
Defeated matching frequency
or lower
Output frequency is lower than
the frequency detection level.
U0.02
≤
F1.08
6 Base
blocking
Blocking the output(during the
contact in putting).
7
Over torque detection
Occurring the over torque
(OL3).
8 Reverse
RUN
9 Current
limiting
Occurring the current(torque)
limiting.
10
Speed searching
Searching the speed.
11 Zero
speed
5-52
MOSCON-E7 User’s Manual
5.7.3 Multi-function analog input
H2.01~H2.07 are used to configure the function of analog inputs.
5.7.3.1 Analog input form : H2.01
Parameter
No.
Name
Unit
Setting
range
Factory
Setting
Changeable
during
operation
H2.01
Analog Input
Type
- 0~3 0
X
• H2.01 is used to configure the function of the analog input when
H2.05=0(frequency command).
• Setting
Setting
constant
Function
0
Frequency Command Vin(Voltage input) (terminal 9)
1
Frequency Command Ain(Current input) (terminal 10)
2
Frequency Command Vin + Ain (9+10)
≤
Fmax
3
Frequency Command Vin – Ain (9-10)
≥
0
5.7.3.2 Analog input filter time constant : H2.02
Parameter
No.
Name
Unit
Setting
range
Factory
Setting
Changeable
during
operation
H2.02
Analog Input
Time Constant
1ms
0~100
20
X
• H2.02 is useful when there are noises in the analog input signal.
• As the value in H2.02 is increased, the noise immunity and the response
time to analog input are increased.