64
TROUBLESHOOTING
4-20) If ICE Water is not supplied
Start
MAIN PBA normal
-- Need to check the other parts
①
Check the wire between Ice
water valve
MAIN PBA
②
Ice water valve itself has trouble
or bad contact of connector
③
Check the connection hose
Normal(Check Ice
water valve hose)
YES
Check soldering
short/Replace PBA
NO
Check soldering
short/Replace PBA
NO
Check soldering
short/Replace PBA
NO
NO
YES
YES
YES
Is the confirming
sound of the valve operation heard
when Ice maker test switch
pushed?
Does Main PBA IC73
#4 have high (5V)output?
Does Main PBA IC73
#15 have about 0.7V
output?
Is the contact point
of Main PBA RELAY RY7B
normal?
Содержание LS3165H52HR
Страница 52: ...54 TROUBLESHOOTING Diode Voltage of IPM ...
Страница 69: ...72 PCB DIAGRAM 6 3 Connector Arrangement Main Board ...
Страница 70: ...73 PCB DIAGRAM 6 4 Connector Layout Description Inverter comp control Board Used for Inverter Model ...
Страница 71: ...69 5 WIRING DIAGRAM ...
Страница 72: ...74 7 1 Block Diagram 7 SCHEMATIC DIAGRAM ...
Страница 73: ...75 SCHEMATIC DIAGRAM 7 2 Block Diagram INVERTER PBA DC 13 2V 5V ...
Страница 76: ...EXPLODED VIEW 1 FREEZER ...
Страница 78: ...15 EXPLODED VIEW 2 FRIDGE 16 ...
Страница 83: ...1 7 1 8 4 5 7 3 8 2 8 3 11 10 12 EXPLODED VIEW 4 DOOR FRE 4 6 9 3 13 ...
Страница 85: ...3 4 5 1 3 2 2 3 3 3 4 3 4 1 3 1 6 EXPLODED VIEW 5 DOOR REF IN ...
Страница 87: ...3 3 1 2 1 1 1 4 1 5 1 6 1 7 4 EXPLODED VIEW 6 DOOR REF OUT 1 ...