80 | SAMLEX AMERICA INC.
Name
Description
Device Info
Product Name
Model of this product
Description
User defined in “Control” page
Location
User defined in “Control” page
MAC Address
MAC Address of this unit
System Up Time
Total time elapsed since turning on this unit
Temperature
DC to DC
Temperature in Celsius sensed by NTC-1 near Heat Sink for DC-DC conversion MOSFETS
DC to AC
Temperature in Celsius sensed by NTC-2 near Heat Sink for DC-AC conversion IGBTS
Warning (Status)
Fan Fault
(Green) Normal / (Red) Warning
Over Voltage Alarm
Under Voltage Alarm
Overload
Over Temperature
Over Voltage Protection
Under Voltage Protection
Short Circuit
Output
CFG. Voltage
Output voltage VAC (RMS) configured (programmed) by the user
Inv. Voltage
Real-Time output voltage VAC (RMS)
Grid. Voltage
Real-Time output voltage VAC (RMS)
Inv. Current
Real-Time output current A (RMS)
Grid. Current
Real-Time output current A (RMS)
Inv. Power
Real-Time output power (W)
Grid. Power
Real-Time output power (W)
CFG. Frequency
Output AC frequency (HZ) configured (programmed) by the user
Inv. Frequency
Real-Time output AC frequency (HZ)
Grid. Frequency
Real-Time output AC frequency (HZ)
Input
Vin
Real-Time input DC voltage (V)
OVP
Over Voltage Protection (V) configured (programmed) by the user
OVP Recovery
OVP recovery voltage (V) configured (programmed) by the user
UVP
Under Voltage Protection (V) configured (programmed) by the user
UVP Recovery
UVP recovery voltage (V) configured (programmed) by the user
OV Alarm
Over Voltage Alarm (V) configured (programmed) by the user
UV Alarm
Under Voltage Alarm (V) configured (programmed) by the user
Status
Fan
on / off
Bypass Relay
Inverter / Grid AC
Bypass Mode
On-Line / Off-Line
Grid AC
Not exists / detect / Present / Sync / Won’t Sync
OL. Percentage
Overload percentage configured (programmed) by the user
Sync. Frequency
Synchronization Frequency Window configured
User Interface
LCD Contrast
LCD contrast configured by the user
LCD Auto-Off
LCD backlight auto-off time configured (programmed) by the user
RS-232 Speed
RS-232 COM Port Baudrate configured (programmed) by the user
USB Virtual COM
USB Virtual COM Baudrate configured (programmed) by the user
User Interface
Buzzer Setup
(Green) ON / (Red) OFF configured (programmed) by the user
Dry Contact Setup
Fig 13.2 Description of Items displayed in Dashboard at Fig 13.1