SAMLEX AMERICA INC. | 27
SECTION 6 |
Layout
6.1 LAYOUT
Layouts of the Front and Back Panels are shown in Figs 6.1 and 6.2 below:
9
9
21
20
12
13
20
20
20
10
11
17
17
21
1
2 3 4 5
6
8a 8b
7
14
15
16
18
19
AC GRID
INVERTER
BYPASS
ALARM
ON
OFF
EXT. Switch
1200W Pure Sine Wave Inverter
PSR-1200-24
ENB
GND
ENB
NC
COM.
NO
RS-232
ETHERNET
CHASSIS GROUND
AC OUTPUT
Fig 6.1 Front view and layout of Front Panel (With mounting brackets)
9
9
21
20
12
13
20
20
20
10
11
17
17
21
1
2 3 4 5
6
8a 8b
7
14
15
16
18
19
AC GRID
INVERTER
BYPASS
ALARM
ON
OFF
EXT. Switch
1200W Pure Sine Wave Inverter
PSR-1200-24
ENB
GND
ENB
NC
COM.
NO
RS-232
USB
ETHERNET
CHASSIS GROUND
AC OUTPUT
Fig 6.2 Rear view and layout of Rear Panel (Without mounting brackets)
LEGEND FOR FIGS 6.1 AND 6.2
1. 3-Position Rocker Switch
i.
OFF: (Centre position). Switches OFF the Inverter Section when under manual On/Off control
ii. ON: (Press top portion). Switches ON the Inverter Section when under manual On/Off control
iii. EXT. Switch (Press bottom portion). Activates External On/Off Control of the Inverter Section
2. 2-Color Status LED marked “AC GRID” – Green / Orange
3. 2-Color Status LED marked “INVERTER” – Green or Red
4. Single color Status LED marked “BYPASS” – Green
5. Single Color Status LED marked “ALARM” – Orange
6. LCD Display: 2 lines of 16 characters each
7. Display Selection Keys for navigating through the LCD Display Screens and for programming
8(a). Air inlet slots for 3 cooling fans (fans located behind the slots – not visible)
8(b). 3 cooling fans located behind the inlet slots 8(a) [ the fans are not visible from outside]
9. Mounting brackets for rack-mount installation
10. Negative (-) DC Input Terminal
11. Positive (+) DC Input Terminal
12. 7-Way Terminal Block: (i) Moving cage clamp terminals (ii) Terminal hole size: 3mm x 2.5mm. The terminal block is used for the following:
a) 3 terminals marked “ENB, GND and ENB” for wired remote On / Off control:
b) 3 terminals marked “NO, COM and NC” for SPDT relay output connections for remote signaling of alarm / fault conditions
13. 9-pin DB-9 Connector for RS-232 communication
14. USB Type “B” Jack for USB connection
15. RJ-45 Jack for Ethernet connection
16. Equipment Grounding connection (metal chassis Ground)
17. NEMA5-20R, Duplex AC Outlet
18. 120 VAC Male Power Inlet Connector: IEC 60320, C14.
NOTE: AC Power Cord with mating Female IEC 60320, C13 connector on one end and NEMA5-15P Plug on the other end has
been provided with the unit for 120VAC input connection
19. AC Input Breaker: 120 VAC, 15A
20. Ventilation slots for air discharge for 3 cooling fans [8(b)] located in the front
21. Handles
Cylindrical hole with Set Screw (i) Hole Diameter: 7/16”,
(ii) Set Screw: 5/16” X 24TPI; 1/2” Length; Slotted Head
Cylindrical hole with Set Screw (i) Hole Diameter: 5/16”,
(ii) Set Screw: 5/16” X 24TPI; 3/8” Length; Slotted Head