SAMLEX AMERICA INC. | 73
SECTION 12 |
Remote Parameter Monitoring & Setup Using
USB / RS-232 Serial Communication Protocol
First, open Tera Term, and choose “Serial” and select
corresponding COM Port:
Second, choose “Setup” -> “Terminal” to open
“Terminal” dialog:
12.5 INTERFACE COMMAND
The buffer size used for communication is 30 bytes. This unit will ignore all bytes more than this value.
During transmission, this unit will reply corresponding information to a computer according to the
commands sent by the user.
When a LF character (ASCII code 0x0A) is received, this unit will begin to interpret the received information
(case-sensitive) and execute the command, if it is valid.
When the unit receives an invalid command or fails to execute, the unit will reply “Invalid Command.”
Set “CR+LF” for New-line Transmit, and check “Local
echo”.
Third, set Baudrate to the corresponding value.