Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 11 of 28
5.1
Equipotential bonding/Grounding
Fig. 5-1 ExCam XPT Q6075 equipotential bonding
Equipotential bonding/grounding of the camera body is absolutely necessary, in order to
avoid static charges and formation of sparks. For this purpose, a screw terminal is provided
at the rear side, at the bottom (right) (see Figure 5.1). The cross-section of the equipotential
bonding should comply with the National Ground Rules (at least 4 mm
2
).
Wiring table:
Potential
Colour (IEC 60757)
Cross-sec-
tion
Comment
PA
GN/YE
4 mm
2
(rigid)
-