Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 15 of 28
Attention!
Perform the foiling up to about 10mm to the terminals, in order to pre-
vent alien crosstalk. Make sure that the foiling cannot cause any short
circuit of the data couples!
Attention!
Bring the twisted pair composite approximately 10mm close to the ter-
minals, in order to ensure the immunity to disturbance.
Attention!
Use only terminals approved by SAMCON.
Attention!
Finally, check your network installation by per Class-D Link Test.
5.3
External connection and protection
There are several options of assigning the ExTB-3 terminal box in a safe area:
5.3.1
Direct routing from the ExTB-3 into the safe area
Fig 5-7 ExTB-3 -> Safe area
In the case of direct routing from ExTB-3 into the safe area, the power supply and the
voltage signal is led from the safe area to the terminal box. Please observe the terminal
box assignment, as described above.