Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 24 of 28 

Network access and visualization 

 
The most  important  procedures  of  the first  starting  up the  camera are  described  below. 
The configuration menu of the web surface allows an intuitive navigation and offers several 
configuration possibilities. For detailed documentation and information how to use the web 
Interface, please see the User Manual for Axis or visit the following website: 
 

https://www.axis.com/products/axis-q6075

 

 
 
 
 
 
 
At delivery, the ExCam XPT Q6075 is set to the applicable net frequency (50Hz or 60Hz). 
If the camera is used at a location with a differing net frequency, a flickering of the picture 
might be noticeable, particularly in surroundings with fluorescent tubes. In such a case, the 
applicabl

e settings have to be carried out within the menu “System Options > Advanced > 

Plain Config”.  
 
User:   

root 

Password:   root 
 
 

7.1 

Browser Support 

 
A list of the currently supported web browsers, operating systems, required add-ons, etc. 
can be viewed at: 
 

http://www.axis.com/techsup/cam_servers/tech_notes/browsers.htm

 

 
 
 
 
 
 
 

7.2 

Assigning the IP address 

 
The  ExCam  XPT  Q6075  is  intended  for  use  in  an  Ethernet  network  and  requires  an  IP 
address to access and control it. In the most today’s networks, a DHCP server is integrated. 
This server automatically assigns an IP address. 
 
If there  is no DHCP  server available  in  the network, the ExCam IP’s default address  is 

192.168.0.90” (subnet masking 255.255.255.0)

Содержание ExCam XPT Q6075

Страница 1: ...ExCam XPT Q6075 User Manual User Manual...

Страница 2: ...ice terminal box 12 5 3 External connection and protection 15 5 3 1 Direct routing from the ExTB 3 into the safe area 15 5 3 2 Routing via ExConnection Rail optional accessories 16 5 3 3 Appropriate c...

Страница 3: ...6 Fig 5 9 Barrier gland 18 Fig 5 10 Cable kit plug play connection package 19 Tab 5 11 Available cable kits 20 Tab 5 12 Recommendation for fusing 21 Fig 5 13 Plug assignment RJ45 22 Fig 6 1 Axis IP Ut...

Страница 4: ...eries is certified both in accordance with the European ATEX and interna tional directive IECEx The explosion protected housing is approved for the ATEX group II for zones 1 2 21 and 22 including the...

Страница 5: ...PoE Power input Permissible temperature range 0 C Tamb 60 C Power supply PoE IEEE 802 3at class 4 Reference voltage 48 VDC 44 54 VDC Maximum power consumption 17 1 W Typical power consumption 11 W 2 3...

Страница 6: ...n video technical data of AXIS https www axis com products axis q6075 2 5 Other technical data Camera Ex d Terminal box Ex e Permissible ambient temperature 0 C 60 C for PoE power supply 50 C 60 C at...

Страница 7: ...pe plate must be observed Alterations are not permitted The camera is to be operated in sound conditions and in the intended way Attention Only original parts of SAMCON Prozessleittechnik GmbH may be...

Страница 8: ...static charge is avoided Attention Please pay attention to the national security installation and accident prevention regulations e g DIN EN 60079 14 and the safety instruc tions given below in this...

Страница 9: ...s a protective cover for the wall bracket The cover protects the cable and cable routing as required by 60079 14 and does not let the cable and cable glands be directly exposed to water splashes Mater...

Страница 10: ...d Attention Please pay attention to the national security installation and accident prevention regulations e g DIN EN 60079 14 and the safety instruc tions given below in this User Manual as well as t...

Страница 11: ...the camera body is absolutely necessary in order to avoid static charges and formation of sparks For this purpose a screw terminal is provided at the rear side at the bottom right see Figure 5 1 The c...

Страница 12: ...Ex e Attention Connect the device the electric mains exclusively via the box ExTB 3 terminal Attention Never open the Ex e terminal box under voltage Attention Adhere to the international installation...

Страница 13: ...B Colour ASKDP03 T IEC60757 Terminal ExTB 3 Cross sec tional sur face Comment Reinforcement YE GN PE 2 5 mm2 Flex Tx WH OG 1 0 26 mm2 Solid conductor Tx OG 2 0 26 mm2 Solid conductor Rx WH GN 3 0 26 m...

Страница 14: ...Doc ID 200514 PT08BA SS ExCam XPT Q6075_en_rev 00 docx Page 14 of 28 Fig 5 5 Sample circuit of terminal box ExTB 3 Fig 5 6 Photo of the occupied terminal box ExTB 3 ExCam XPT Q6075...

Страница 15: ...e immunity to disturbance Attention Use only terminals approved by SAMCON Attention Finally check your network installation by per Class D Link Test 5 3 External connection and protection There are se...

Страница 16: ...ies Fig 5 8 ExTB 3 ExConnection Rail In the case of routing the ExTB 3 into a larger ExConnection Rail larger installation dis tances can be managed Note In explosive areas ExConnection Rail optional...

Страница 17: ...icient cross section The cable protec tion must comply with national and international regulations To see non binding configuration and planning guidelines please visit https www samcon eu fileadmin d...

Страница 18: ...Doc ID 200514 PT08BA SS ExCam XPT Q6075_en_rev 00 docx Page 18 of 28 Video Tutorial Observe our video tutorial SAMCON 02 Installation Ex d gland https go samcon eu v02 Fig 5 9 Barrier gland...

Страница 19: ...ction packages include everything you need for a professional system installation Fig 5 10 Cable kit plug play connection package a b c d 10 25 95 m SKDP03 T system cable digital a 1 x barrier gland w...

Страница 20: ...t includes 25 meters SKDP03 T system cable digital 1 x barrier gland Ex d 5 ml Loctite 243 screw locking 1 x CAT6 RJ45 industrial plug 1 x documentation ASKDP03 T CABLE EXCAM 25M 01545 001 This cable...

Страница 21: ...of continuous power Fine wire fuse L 6000 mA T slow blow high inrush load L 2 BU 1 5Mm2 2 stranded wire 0 VDC GND PE YE GN 1 5Mm2 2 stranded wire PE Tab 5 12 Recommendation for fusing 5 3 6 Plug assig...

Страница 22: ...assignment RJ45 5 3 7 Tests prior to switching on voltage Attention Prior to commissioning all tests as indicated by the national regula tions have to be executed Furthermore the correct function and...

Страница 23: ...o the explosion relevant rules WARNING MAY NOT BE OPENED IN HAZARD AREAS Note Depending on classification of hazard areas a work approval has to be obtained Even after switching on the power supply it...

Страница 24: ...ring net frequency a flickering of the picture might be noticeable particularly in surroundings with fluorescent tubes In such a case the applicable settings have to be carried out within the menu Sys...

Страница 25: ...he device list It can also be used to manually assign a static IP address For this pur pose the ExCam XPT Q6075 network camera has to be installed in the same physical network segment physical subnet...

Страница 26: ...tenance measures are necessary they have to be initiated and or executed 9 Reparation Reparations must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pressure resist...

Страница 27: ...s 3D models All drawings 3D models certificates and other information are available in the download area of the product page on our website https www samcon eu en products network excam xpt q6075 If y...

Страница 28: ...Schillerstra e 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31...

Отзывы: