4
Assembly
Work preparation:
Attention!
Prepare your work carefully and in accordance with the relevant
regulations.
Attention!
Depending on classification of hazard areas, a work approval has to be
obtained. When you open the pressure-resistant enclosure under volt-
age, it is absolutely necessary to prevent potentially explosive atmos-
phere!
To ensure the best image quality delivered by the network camera, plan the installation site
carefully (consider light conditions, object distance or size, angle and minimum object
distance to the focus).
Use appropriate tools and aids
When working, ensure a safe stand.
Make sure that any static charge is avoided
Attention!
Please pay attention to the national security, installation and accident
prevention regulations (e.g. DIN EN 60079-14) and the safety instruc-
tions given below in this User Manual, as well as the ones in the Instal-
lation Guidelines!
Attention!
Adhere to the provisions of the IECEx ATEX and
EX installation instructions for mounting and starting up!
ExCam
®
XPT Q6075 consists of a flame-proof camera housing (Ex-d) and a connection
chamber of a high degree of safety (Ex-e). Both areas are separated by a reinforced 5 m
line.
Mount the camera as high as possible, according to the desired field of view.
Install the connection chamber so that a good accessibility is provided, in order to facilitate
electrical connection.
Attention!
Please pay attention to the national and local regulations for mounting
heavy loads. In case of doubt, take appropriate security measures.