Electrical connection
D
Electrical connection must be carried out by a qualified electrician
−
according to the applicable VDE 0100 directives
−
and the directives of the responsible power supply company.
D
The flexible mains connection must be at least H 07 RN-F.
D
An electric switch (mains switch)
−
must be easily accessible and installed upstream.
−
The switch must effectively disconnect the appliance at all poles from the mains.
−
The contact opening must be at least 3 mm.
D
For safety reasons, we recommend installing a > 10 mA residual-current circuit breaker
(RCCB).
D
Observe the data on the type plate when making the electrical connection.
D
Integrate the appliance into the equipotential bonding system. Its efficiency must be checked
in accordance with VDE0190.
7.3
Connecting cables
.
Loosen screws and remove cover.
.
You require an ”energy optimisation assem
bly kit” for connecting an energy optimising
unit.
.
Securely connect the mains connection
cable at the customer's premises.
D
Do not use a mains plug!
.
Close the panel.
Panel
Screws
Equipotent
ial bonding
connection
Cable
inlet