DLY (DELUXE) SERIES HYDRONIC CASSETTE
.
8
SPECIFICATIONS – 2 PIPE SYSTEM
(4-WAY DISCHARGE SINGLE FAN CASSETTE)
Cooling: Entering air temperature: Dry bulb 27ºC, Wet bulb 19ºC;
Inlet water temp. 7ºC; Outlet water temp. 12ºC;
Heating: Entering air temperature: 20ºC;
Inlet water temp. 50ºC; Same water flow rate as for the cooling;
The customized power of electric heater is available.
The electric heater can be set as auxiliary heater booster or as primary heater, see control specifications.
SFP-85KM4-V/DLY
SFP-102KM4-V/DLY
SFP-136KM4-V/DLY
Total capacity
(H/M/L)
kW
5.5/4.1/3.1
6.1/4.3/3.5
7.1/5.2/4.0
Sensible capacity
(H/M/L)
kW
4.2/3.1/2.3
4.8/3.5/2.9
5.7/4.2/3.2
Water flow rate
L/h
930
990
1,150
Pressure drop
kPa
5.5
7
9.5
Hot Water Heating
Capacity
(H/M/L)
kW
8.4/6.2/4.7
9.1/6.6/5.4
10.5/7.8/6.0
Evaparator Coil
Water content
L
1.84
1.84
1.84
Type
Size (Dia.)
mm
380
380
380
No. of fan
1
1
1
Power supply
V/Ph/Hz
Power input
W
71
84
127
Running current
A
0.33
0.38
0.58
m
3
/h
850/700/530
1020/770/600
1360/1010/780
dB(A)
39/32/29
42/36/33
50/40/33
kW
2.0
2.0
2.0
A
9.0
9.0
9.0
mm
mm
kg
Method
In
mm(in)
Out
mm(in)
19.05(3/4")
19.05(3/4")
Centrifugal type fan blower
830x830x30
29.5
Wireless remote controller and/or Wired wall pad
Socket (Threaded Female)
Water Connection
Chilled Water Cooling
Air Flow (H/M/L)
Electric Power
Panel Dimensions
Operation Control
Fan Blower
Model
701x701x290
Electric Heater (optional)
Sound Pressure (1m,H/M/L)
Net Weight
Unit Dimensions (LxWxH)
SAKURA - Total Air Conditioning Solution