Yes
No
No
Yes
No
Yes
Yes
No
No
Yes
Saijo denki International co.,ltd.
89
Is the supply voltage to
the outdoor unit normal?
Check power voltage
Is there cloging in the
refrigerant system ?
Correct refrigerant system
Is compressor working
normal?
Check compressor
Check control board
Check code
Check code name
cause
Error 42
Compressor1 Inverter Driver Over
Current
The electric current of control board of
compressor 1 is higher than the specified value.
Is there cloging on
outdoor unit heat
exchanger ?
Cleaning
Is outdoor unit fan
motor normal ?
Check fan motor
Содержание CVIA-80-CPF3